Rolling Stock Cables | ||||||||||||||||||
|
FIREROL Thin Wall Multicore Overall Screened Cables with Standard Wall Sheath 300/500 V
EN 50306-4 (FRL-TW-05M-SW-OS)
A.Conductor B.Insulation C.Screen D.Sheath
Application
Used as power and control cable for protected installations inside and outside of rail and transport vehicles,
where handling and installation cost are an important factor.
Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels,
driver desks etc.
Construction
Conductor
Tinned annealed copper wires as defined in EN 50306-2
Insulation
LSZH special compound
Overal screen
Tinned annealed copper wires
Outer sheath
LSZH special compound as defined in EN 50264-1 (S2. EM 101 - EM 104)
Electrical & Mechanical Properties
Nominal Voltage:300/500 V
Maximum Conductor Temperature:+90/+105 deg (fixed installation)
Minimum Permissible Ambient Temperature:-25/-40 deg (fixed installation)
Bending Radius:10 x Overall Diameter
Chemical & Environmental Properties
EN 60684-2:No fluorine
EN 50305; EN 60811-2-1:Resistance to mineral oil & fuel oil, acid & alkali
EN 50305:Resistance to ozone
Fire Performance for rolling stock application
EN 50306-2:Hazard levels HL1, HL2/HL3
DIN 5510-2:Protection level 1/2/3/4
BS 6853:Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101:FO
EN45545-2:R15 Interior/ R16 Exterior HL1, HL2, HL3
Fire Performance in general
EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) | Vertical flame propogation for a single insulated wire or cable |
EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804 |
Vertical flame spread of vertically mounted bunched wires or cables |
EN 50268-2; IEC 61034-2; NF C 32-073 ; NF C 20-902; NF F 16 101; VDE 0472 Teil 816 |
Low Smoke Emission |
EN 50267-2-1; IEC 60754-1; NF C 32-074;NF C 20-454; VDE 0472 Teil 815 | Halogen Free |
EN 50267-2-2/3; IEC 60754-2; NF C 32-074;NF C 20-453; VDE 0472 Teil 813 | Low Corrosivity (Acidity & Conductivity) |
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 | Low Toxicity |
NFF 16101; NFF 63808; BS6853 | Smoke index |
EN45545-2 | Requirement for fire behavior of materials & components R15/R16 |
FRL-TW-05M-SW-OS 300/500 V
NUMBER OF CORES AND NOMINAL CROSS SECTION | MINIMUM THICKNESS OF SHEATH AT ANY POINT | OVERALL DIAMETER | WEIGHT | |
mm² | mm | min. mm |
max. mm |
kg/km |
2 x 0.5 | 0.42 | 4.1 | 5.1 | 30 |
3 x 0.5 | 0.42 | 4.3 | 5.3 | 40 |
4 x 0.5 | 0.42 | 4.7 | 5.7 | 50 |
6 x 0.5 | 0.42 | 5.5 | 6.5 | 70 |
8 x 0.5 | 0.42 | 6.0 | 7.0 | 90 |
2 x 0.75 | 0.42 | 4.5 | 5.5 | 40 |
3 x 0.75 | 0.42 | 4.7 | 5.7 | 50 |
4 x 0.75 | 0.42 | 5.2 | 6.2 | 60 |
6 x 0.75 | 0.42 | 6.1 | 7.1 | 90 |
8 x 0.75 | 0.42 | 6.6 | 7.6 | 110 |
2 x 1.0 | 0.42 | 4.7 | 5.7 | 50 |
3 x 1.0 | 0.42 | 5.1 | 6.0 | 60 |
4 x 1.0 | 0.42 | 5.5 | 6.5 | 80 |
6 x 1.0 | 0.42 | 6.6 | 7.6 | 110 |
8 x 1.0 | 0.56 | 7.7 | 8.7 | 140 |
2 x 1.5 | 0.42 | 5.7 | 6.7 | 70 |
3 x 1.5 | 0.42 | 6.0 | 7.0 | 90 |
4 x 1.5 | 0.42 | 6.6 | 7.6 | 100 |
6 x 1.5 | 0.56 | 8.3 | 9.3 | 160 |
8 x 1.5 | 0.56 | 8.9 | 10.1 | 200 |
2 x 2.5 | 0.56 | 7.3 | 8.3 | 100 |
3 x 2.5 | 0.56 | 7.7 | 8.7 | 130 |
4 x 2.5 | 0.56 | 8.4 | 9.6 | 160 |